Products · Boilers & Heat Recovery

Waste Heat Boilers — WHB

To establish the project design basis for “Waste Heat Boilers — WHB”, confirm “Waste-heat source and steam generation” and its inputs: Define hot-gas source, composition/flow, recoverable-temperature basis, fouling/corrosion and required steam pressure/temperature. Final values, supply limits and acceptance criteria are recorded in approved engineering documents; no generic capacity or catalogue guarantee is assumed.

Waste Heat Boilers — WHB

From project definition to delivery

Engineering intent and design approach

Engineering of Waste Heat Boilers — WHB concentrates on gas and steam temperature profiles, pinch and approach temperatures, steam conditions, circulation, gas-side pressure drop, water chemistry, metallurgy, fouling and start-up transients. The selected configuration is verified against normal, minimum, start-up, shutdown and credible upset cases, then checked for operability, maintainability, energy use, process safety and site interfaces before the design is frozen.

The design basis for Waste Heat Boilers — WHB is defined from service data, design conditions, and battery limits. For this equipment, Waste-heat source and steam generation and Feed and thermal conditions must be completed in the datasheet and design documents; performance values and guarantees are set only after the project basis is approved.

Mechanical design and materials

Materials, corrosion allowance, sour-service requirements, piping classes, nozzle design, insulation, coating, supports and maintenance access are coordinated with the actual process conditions and project code hierarchy.

Control, safeguarding and operation

Control philosophy, alarms and trips, cause-and-effect logic, interlocks, start-up and shutdown sequences, safe depressurization and operator access are developed consistently from the P&IDs through functional testing.

Layout, utilities and interfaces

Battery limits, tie-in points, structural loads, cabling, instrumentation, drains, vents, access routes, lifting envelopes and shipping constraints are controlled through coordinated models and interface drawings.

From project definition to delivery

Clear inputs and contract-ready outputs

Proposal quality depends on complete input data and an explicit acceptance basis. The following lists provide a practical starting point and are completed during technical clarification.

Recommended RFQ information

  • “Feed and thermal conditions”: Record feedwater/process-gas quality/flow, fuel, hot-gas conditions, inlet/outlet temperature and fouling/corrosion.
  • “Heat-transfer and pressure parts”: Specify circulation, heat-transfer surface, coils/tubes, drum if needed, economizer/superheater and cleaning strategy.
  • Site and ambient data, hazardous-area classification and HSE requirements
  • Available utilities with pressure, temperature and capacity
  • Applicable standards, materials, supply limits and owner document formats

Typical engineering and supply deliverables

  • Equipment datasheet and design basis for “Waste Heat Boilers — WHB”, with service-relevant calculations where included in the supply scope.
  • PFDs, P&IDs, equipment list and technical datasheets
  • Control philosophy, cause and effect, I/O definition and utility summary
  • Plot plan, 3D model, foundation loads and fabrication drawings
  • Inspection and test plans, FAT records, final data book and commissioning support

Technical Datasheet

Technical Datasheet — Waste Heat Boilers — WHB

This is a published high-pressure water-tube WHB family for hot combustion flue gas. It is a product/sector reference—not a universal WHB range or a project guarantee.

Published equipment-family or project data only; not a universal standard limit or Delham rating/guarantee.
ParameterPublished valueReference basisApplicability / limit
Superheated-steam power30–90 MWPublished range for a high-pressure waste-heat steam-boiler product family.The cited range is associated with energy/biomass exhaust-gas service; available heat and steam conditions govern.
Steam pressure40–90 bar(g)Published steam-pressure span for the same WHB family.Pressure is not a stand-alone rating; steam flow, temperature, circulation, materials and pressure-boundary code must be designed together.
Hot-flue-gas temperature reference450–550 °CPublished inlet-temperature range in the cited energy-recovery application.Source gas composition, fouling, ash/alkali, corrosion and allowable outlet temperature may change the surface arrangement and duty.

Published technical source

Delham Engineering

Define the scope around real project data

Send the available process data, battery limits and expected document list for a technical proposal. The engineering team will identify missing information through a structured clarification register.

Submit technical enquiry