Products · Boilers & Heat Recovery

Economizers

To establish the project design basis for “Economizers”, confirm “Hot-side/cold-side heat-recovery basis” and its inputs: Specify hot-gas flow/composition, water flow and conditions, inlet/outlet temperatures, fouling/dew-point basis and allowable pressure drop. Final values, supply limits and acceptance criteria are recorded in approved engineering documents; no generic capacity or catalogue guarantee is assumed.

Economizers

From project definition to delivery

Engineering intent and design approach

Engineering of Economizers concentrates on gas and steam temperature profiles, pinch and approach temperatures, steam conditions, circulation, gas-side pressure drop, water chemistry, metallurgy, fouling and start-up transients. The selected configuration is verified against normal, minimum, start-up, shutdown and credible upset cases, then checked for operability, maintainability, energy use, process safety and site interfaces before the design is frozen.

The design basis for Economizers is defined from service data, design conditions, and battery limits. For this equipment, Hot-side/cold-side heat-recovery basis and Exchanger sides and outlet conditions must be completed in the datasheet and design documents; performance values and guarantees are set only after the project basis is approved.

Mechanical design and materials

Materials, corrosion allowance, sour-service requirements, piping classes, nozzle design, insulation, coating, supports and maintenance access are coordinated with the actual process conditions and project code hierarchy.

Control, safeguarding and operation

Control philosophy, alarms and trips, cause-and-effect logic, interlocks, start-up and shutdown sequences, safe depressurization and operator access are developed consistently from the P&IDs through functional testing.

Layout, utilities and interfaces

Battery limits, tie-in points, structural loads, cabling, instrumentation, drains, vents, access routes, lifting envelopes and shipping constraints are controlled through coordinated models and interface drawings.

From project definition to delivery

Clear inputs and contract-ready outputs

Proposal quality depends on complete input data and an explicit acceptance basis. The following lists provide a practical starting point and are completed during technical clarification.

Recommended RFQ information

  • “Exchanger sides and outlet conditions”: Provide hot-gas flow/composition, water flow/quality, inlet/outlet temperatures on both sides and allowable pressure drops.
  • “Fouling, corrosion and cleaning”: Define gas contaminants, potential corrosive dew point, fouling, cleaning intervals and any bypass requirement.
  • Site and ambient data, hazardous-area classification and HSE requirements
  • Available utilities with pressure, temperature and capacity
  • Applicable standards, materials, supply limits and owner document formats

Typical engineering and supply deliverables

  • Equipment datasheet and design basis for “Economizers”, with service-relevant calculations where included in the supply scope.
  • PFDs, P&IDs, equipment list and technical datasheets
  • Control philosophy, cause and effect, I/O definition and utility summary
  • Plot plan, 3D model, foundation loads and fabrication drawings
  • Inspection and test plans, FAT records, final data book and commissioning support

Technical Datasheet

Technical Datasheet — Economizers

The product range and boiler-performance change below come from published exhaust-gas economizer data. Actual recovery depends on fuel, feedwater conditions, stack-corrosion margin and boiler duty.

Published equipment-family or project data only; not a universal standard limit or Delham rating/guarantee.
ParameterPublished valueReference basisApplicability / limit
Economizer heat-exchanger capacity100–600 kWPublished exhaust-gas economizer family for hot-water and steam boilers.This is a product-family range; duty must be recalculated from flue-gas flow/temperature and feedwater conditions.
Additional output on selected steam-boiler models24–52 kWPublished increment for 500–1,500 kg/h boiler models with economizer at 10 bar(g).Model- and fuel-specific comparison; it is not a general percentage or a retrofit guarantee.
Published boiler-efficiency example88% minimum without / 94% with economizerPublished natural-gas data for the cited boiler models at the stated operating basis.Check LHV/HHV basis, feedwater inlet, stack temperature, excess oxygen and condensation/corrosion limits before comparison.

Published technical source

Delham Engineering

Define the scope around real project data

Send the available process data, battery limits and expected document list for a technical proposal. The engineering team will identify missing information through a structured clarification register.

Submit technical enquiry