Packages · Process Packages

Molecular Sieve Dehydration Packages

To establish the project design basis for “Molecular Sieve Dehydration Packages”, confirm “Water load and bed-regeneration cycle” and its inputs: Define gas composition and flow, inlet/outlet water basis, pressure/temperature, bed count/arrangement and regeneration-cycle options. Final values, supply limits and acceptance criteria are recorded in approved engineering documents; no generic capacity or catalogue guarantee is assumed.

Molecular Sieve Dehydration Packages

From project definition to delivery

Engineering intent and design approach

Engineering of Molecular Sieve Dehydration Packages concentrates on water-dew-point guarantee, glycol or adsorbent selection, contactor or bed sizing, regeneration duty, carry-over control, emissions and switching philosophy. The selected configuration is verified against normal, minimum, start-up, shutdown and credible upset cases, then checked for operability, maintainability, energy use, process safety and site interfaces before the design is frozen.

The design basis for Molecular Sieve Dehydration Packages is defined from service data, design conditions, and battery limits. For this equipment, Water load and bed-regeneration cycle and Feed and outlet specification must be completed in the datasheet and design documents; performance values and guarantees are set only after the project basis is approved.

Mechanical design and materials

Materials, corrosion allowance, sour-service requirements, piping classes, nozzle design, insulation, coating, supports and maintenance access are coordinated with the actual process conditions and project code hierarchy.

Control, safeguarding and operation

Control philosophy, alarms and trips, cause-and-effect logic, interlocks, start-up and shutdown sequences, safe depressurization and operator access are developed consistently from the P&IDs through functional testing.

Layout, utilities and interfaces

Battery limits, tie-in points, structural loads, cabling, instrumentation, drains, vents, access routes, lifting envelopes and shipping constraints are controlled through coordinated models and interface drawings.

From project definition to delivery

Clear inputs and contract-ready outputs

Proposal quality depends on complete input data and an explicit acceptance basis. The following lists provide a practical starting point and are completed during technical clarification.

Recommended RFQ information

  • “Feed and outlet specification”: Record feed phase/composition, relevant contaminants, water/solids/salts/hydrocarbons, product/effluent targets and pressure-drop limit.
  • “Technology and process arrangement”: Select separation/treatment method, stages/internals, chemicals/adsorbent, filtration and standby options from feed analysis.
  • Site and ambient data, hazardous-area classification and HSE requirements
  • Available utilities with pressure, temperature and capacity
  • Applicable standards, materials, supply limits and owner document formats

Typical engineering and supply deliverables

  • Equipment datasheet and design basis for “Molecular Sieve Dehydration Packages”, with service-relevant calculations where included in the supply scope.
  • PFDs, P&IDs, equipment list and technical datasheets
  • Control philosophy, cause and effect, I/O definition and utility summary
  • Plot plan, 3D model, foundation loads and fabrication drawings
  • Inspection and test plans, FAT records, final data book and commissioning support

Technical Datasheet

Technical Datasheet — Molecular Sieve Dehydration Packages

A sourced market or engineering reference is shown below, not a code-mandated envelope, Delham rating, or project guarantee. Confirm the service basis before using it.

Published equipment-family or project data only; not a universal standard limit or Delham rating/guarantee.
ParameterPublished valueBasis / secondary dataApplication limit
Cryogenic-service outlet moisture target<0.1 ppmv H₂OPublished LNG/cryogenic design target for molecular-sieve dehydration.Service-specific outlet target, not a universal package guarantee; confirm downstream freezing limits and test basis.

Published technical source

Delham Engineering

Define the scope around real project data

Send the available process data, battery limits and expected document list for a technical proposal. The engineering team will identify missing information through a structured clarification register.